JAEST LOGO

Authors

Mohamed-Ali Djebiret Unité de Développement des Équipements Solaires, UDES/Centre de Développement des Énergies Renouvelables, CDER, Bou Ismail, 42415, W. Tipaza, Algeria Author
Brahim Abbad Unité de Développement des Équipements Solaires, UDES/Centre de Développement des Énergies Renouvelables, CDER, Bou Ismail, 42415, W. Tipaza, Algeria Author
Adel Benchabane Université Mohamed Khider Biskra, Laboratoire de Génie Energétique et Matériaux (LGEM), Faculté des Sciences et de la Technologie, Biskra 07 000, Algeria Author
Maamar Ouali Unité de Développement des Équipements Solaires, UDES/Centre de Développement des Énergies Renouvelables, CDER, Bou Ismail, 42415, W. Tipaza, Algeria Author
Ferhat Yahi Unité de Développement des Équipements Solaires, UDES/Centre de Développement des Énergies Renouvelables, CDER, Bou Ismail, 42415, W. Tipaza, Algeria Author
Mohand Berdja Unité de Développement des Équipements Solaires, UDES/Centre de Développement des Énergies Renouvelables, CDER, Bou Ismail, 42415, W. Tipaza, Algeria Author
Amar Rouag Université Kasdi Merbah Ouargla, Laboratoire de développement des Energies Nouvelles et Renouvelables dans les Zones Arides et Sahariennes, LENREZA, BP 511, Ouargla 30000, Algeria Author

DOI:

https://doi.org/10.69717/jaest.v4.i2.77

Keywords:

Experimental device, Solar refrigeration, Adsorption, Activated carbon, Methanol, COP

Abstract

This work presents an experimental study of a solar adsorption refrigeration device using activated carbon AC-35 /methanol as working pair. The studied device is designed, realized and tested in the Development of Solar Equipment Unit, UDES, Tipaza (Algeria). The adsorption and desorption tests, carried out on the experimental device, were conducted inside the laboratory using a halogen lamp as an energy source instead the sun. The lamp is installed perpendicularly to the surface of the tubular adsorber to test four radiation levels: 800, 820, 1000 and 1020 W/m². A calculation code is developed, using the Dubinin-Astakhov mathematical model, to evaluate the thermodynamic coefficient of performance, COP th , of the experimental device. Thus, a parametric study is presented to examine the influence of the construction material and the weight of the adsorber on the COP th , the amount of cold produced in the evaporator, Qf, and the total heat supplied to the system, Qc.

Downloads

Download data is not yet available.

Downloads

Published

2018-06-22

Issue

Section

Research Paper

How to Cite

Experimental study of solar adsorption refrigeration device. (2018). Journal of Applied Engineering Science & Technology, 4(2), 8. https://doi.org/10.69717/jaest.v4.i2.77

Similar Articles

21-30 of 30

You may also start an advanced similarity search for this article.